Tripp Lite OmniVS Series 1000VA Line-Interactive
Tripp Lite OmniVS Series 1000VA Tower Line-Interactive 230V UPS with USB port
Share Product
- Availability:
- Out Of Stock
- Product Code:
- OMNIVSINT1000
JOD 165.00
Chat with us on Whatsapp
-
Free delivery on orders Over 100 JOD
-
Cash on Delivery
OUTPUT | |
---|---|
Output Volt Amp Capacity (VA) | 1000 |
Output Watt Capacity (watts) | 500 |
Nominal Output Voltage(s) Supported | 220V; 230V; 240V |
Nominal Voltage details | 230V inverter nominal voltage output |
Frequency compatibility | 50 / 60 Hz |
Output voltage regulation (Battery mode) | +/- 5% |
Built-in UPS output receptacles | 6 C13 outlet(s) |
Included output power cables | Includes 2 C13 to C14 output power cables |
Output AC waveform (AC mode) | Sine wave |
Output AC waveform (battery mode) | PWM sine wave |
INPUT | |
Rated input current (at maximum load) | 2.4A |
Nominal Input Voltage(s) Supported | 230V AC |
UPS input connection type | C14 inlet |
UPS input connection description | Attached 15cm line cord with C14 inlet. The C14 inlet accepts a user-supplied AC power cord with country specific plug. |
UPS Input cord length (ft.) | 0.5 |
UPS Input cord length (m) | 0.2 |
BATTERY | |
Full load runtime (minutes) | 5 min. (500w) |
Half load runtime (minutes) | 12 min. (250w) |
DC system voltage (VDC) | 12 |
Battery recharge rate (included batteries) | Less than 9 hours from 10% to 90% |
Replacement battery cartridge (internal UPS battery replacement) | RBC51 |
Battery Access | Battery access door |
Battery replacement description | Hot-swappable, user replaceable batteries |
VOLTAGE REGULATION | |
Voltage regulation description | Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 159 |
Undervoltage correction | Input voltages between 159 and 199 are boosted by 14% |
LEDS ALARMS & SWITCHES | |
LED Indicators | 4 LEDs indicate line power, battery power, overload and battery low/replace status |
Alarms | Audible alarm indicates power-failure and low-battery conditions |
Alarm cancel operation | Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
SURGE / NOISE SUPPRESSION | |
UPS AC suppression joule rating | 508 |
UPS AC suppression response time | Instantaneous |
UPS Dataline suppression | 1 line TEL/DSL (1 in / 1 out) |
EMI / RFI AC noise suppression | Yes |
PHYSICAL | |
Installation form factors supported with included accessories | Tower |
Installation form factors supported with optional accessories | Wallmount (UPSWM - tower mounting kit) |
Primary form factor | Tower |
UPS / Power Module dimensions in primary form factor (height x width x depth / inches) | 10.8 x 5.2 x 7.5 |
UPS / Power Module dimensions in primary form factor (height x width x depth / cm) | 27.3 x 13.3 x 19 |
UPS / Power Module weight (lbs) | 16.7 |
UPS / Power Module weight (kg) | 7.6 |
UPS Shipping dimensions (height x width x depth / inches) | 14 x 8.5 x 11 |
UPS Shipping dimensions (height x width x depth / cm) | 35.6 x 21.6 x 27.9 |
Shipping weight (lbs) | 19.7 |
Shipping weight (kg) | 8.9 |
UPS housing material | PVC |
ENVIRONMENTAL | |
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity | 0 to 95%, non-condensing |
AC mode BTU / hr. (full load) | 147.8 |
Battery mode BTU / hr. (full load) | 254 |
COMMUNICATIONS | |
Communications interface | USB |
PowerAlert software | Free download from www.tripplite.com |
Communications cable | USB interface cable included |
WatchDog compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
LINE / BATTERY TRANSFER | |
Transfer time | 4 milliseconds |
Low voltage transfer to battery power (setpoint) | 159 |
High voltage transfer to battery power (setpoint) | Yes |
SPECIAL FEATURES | |
Cold Start (startup in battery mode during a power failure) | Cold-start operation supported |
High availability UPS features | Hot swappable batteries |
CERTIFICATIONS | |
UPS Certifications | CE; Tested to GOST (Russia); Tested to SASO (Saudi Arabia); Tested to IRAM (Argentina); Meets FCC Part 15 Category B (EMI) |
UPS Certification details | CE IEC62040 |